OD1-B015C05I25 10 mm ... 20 mm 1 µm ± 10 µm 700 µm x 500 µm (15 mm) Cable with male connector, M12, 5-pin, 30 cm Aluminum housing with PPSU lens 1 x 4 mA ... 20 mA (< 300 Ω)

Part No. 6050520

At a glance

  • Compact, robust housing
  • Integrated amplifier unit, no additional unit necessary
  • Display and LEDs on device for visualization of current status
  • Wide range of interfaces available
  • Simple teach-in using display or external teaching input
  • CMOS receiver unit for precise, fast measurement in the µm range
  • Different measuring ranges enabling measurement from 10 mm up to 250 mm

Your benefits

  • Cost-saving commissioning through simple operating concept and display
  • Small installation size and low weight also allow use in highly dynamic applications
  • Reduction in cabling, as no additional amplifier unit is necessary
  • High machine throughput thanks to reliable measurement, regardless of brightness and color of surface
  • The wide range of available interfaces enables simple integration into industrial networks
  • Optimum performance even at high production speeds

Performance

Measuring range: 10 mm ... 20 mm
Resolution 1): 1 µm
Repeatability 2) 3): 3 µm
Linearity 4) 5): ± 10 µm
Response time 6): 2 ms / 4 ms / 8 ms / 16 ms / auto
Measuring frequency: 2 kHz / 1 kHz / 500 Hz / 250 Hz / auto
Light source: Laser, Red
Typ. light spot size (distance): 700 µm x 500 µm (15 mm)
Additional function: Automatic or manual sensitivity adjustment, Teach-in of analog outputs, Teach-in of switching outputs, Switching output invertible, Averaging 1 ... 512x, Multifunctional input: laser-off / external teach-in / trigger, Switching mode: distance to object (DtO), Switching mode: window (Wnd), Switiching mode: object between sensor and background (ObSB)
Laser class: 1 (EN 60825-1) 7)
1) 2) Averaging function set to: 512  3) Constant ambient conditions  4) Measurement on 90 % remission (ceramic, white)  5) For best performance consider warm up time ≤ 5 minutes  6) At fixed sensitivity setting and averaging = 1. With automatic sensititvity setting and sample rating 500 µs: 2 ... 7.5 ms response time/sample rating 1,000 µs: 4 ... 15 ms response time  7) Wavelength: 655 nm, max. output: 390 µW (laser class 1) / < 1 mW (laser class 2)  

 

Interfaces

Data interface: 1 x 4 mA ... 20 mA (< 300 Ω)
Output type: 1 x PNP/NPN, selectable
Multifunctional input (MF) 1): 1 x
1) MF can be used as laser-off, trigger, external teach-in or deactivated  

 

Mechanics/electronics

Connection type: Cable with male connector, M12, 5-pin, 30 cm
Supply voltage Vs: DC 12 V (-5 %) ... DC 24 V (+10 %)
Power consumption 1): ≤ 1.92 W
Warm-up time: ≥ 5 min
Indication: 4-digit 7-segment display (plus 4 LEDs for status display)
Operating elements: 4 buttons
Weight: 40 g
Dimensions: 44.4 mm x 31 mm x 17 mm
Housing material: Aluminum housing with PPSU lens
1) Without load, with current output  

 

Ambient data

Enclosure rating: IP 67
Protection class: III
Ambient temperature: Operation: -10 ... +40 °C, Storage: -20 ... +60 °C
Min. rel. humidity (not condensing): 35 %
Max. rel. humidity (not condensing): 95 %
Temperature drift: ± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor)
Vibration resistance: 10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each)
Shock resistance: 50 G (x-, y-, z-axis 3 times each)
Typ. Ambient light immunity: Artificial light: ≤ 3,000 lx, Sunlight: ≤ 10,000 lx
 

 

General notes

Note: Not free of paint wetting impairment substances.