DataSheet:
Part No. 6050495
At a glance
- Compact, robust housing
- Integrated amplifier unit, no additional unit necessary
- Display and LEDs on device for visualization of current status
- Wide range of interfaces available
- Simple teach-in using display or external teaching input
- CMOS receiver unit for precise, fast measurement in the µm range
- Different measuring ranges enabling measurement from 10 mm up to 250 mm
Your benefits
- Cost-saving commissioning through simple operating concept and display
- Small installation size and low weight also allow use in highly dynamic applications
- Reduction in cabling, as no additional amplifier unit is necessary
- High machine throughput thanks to reliable measurement, regardless of brightness and color of surface
- The wide range of available interfaces enables simple integration into industrial networks
- Optimum performance even at high production speeds
Performance |
|||
![]() |
Measuring range: | 10 mm ... 20 mm |
![]() |
![]() |
Resolution 1): | 1 µm |
![]() |
![]() |
Repeatability 2) 3): | 3 µm |
![]() |
![]() |
Linearity 4) 5): | ± 10 µm |
![]() |
![]() |
Response time 6): | 2 ms / 4 ms / 8 ms / 16 ms / auto |
![]() |
![]() |
Measuring frequency: | 2 kHz / 1 kHz / 500 Hz / 250 Hz / auto |
![]() |
![]() |
Light source: | Laser, Red |
![]() |
![]() |
Typ. light spot size (distance): | 700 µm x 500 µm (15 mm) |
![]() |
![]() |
Additional function: | Automatic or manual sensitivity adjustment, Teach-in of analog outputs, Teach-in of switching outputs, Switching output invertible, Averaging 1 ... 512x, Multifunctional input: laser-off / external teach-in / trigger, Switching mode: distance to object (DtO), Switching mode: window (Wnd), Switiching mode: object between sensor and background (ObSB) |
![]() |
![]() |
Laser class: | 1 (EN 60825-1) 7) |
![]() |
![]() |
1) 2) Averaging function set to: 512 3) Constant ambient conditions 4) Measurement on 90 % remission (ceramic, white) 5) For best performance consider warm up time ≤ 5 minutes 6) At fixed sensitivity setting and averaging = 1. With automatic sensititvity setting and sample rating 500 µs: 2 ... 7.5 ms response time/sample rating 1,000 µs: 4 ... 15 ms response time 7) Wavelength: 655 nm, max. output: 390 µW (laser class 1) / < 1 mW (laser class 2) |
![]() |
Interfaces |
|||
![]() |
Data interface: | 1 x 4 mA ... 20 mA (< 300 Ω) |
![]() |
![]() |
Multifunctional input (MF) 1): | 1 x |
![]() |
![]() |
1) MF can be used as laser-off, trigger, external teach-in or deactivated |
![]() |
Mechanics/electronics |
|||
![]() |
Connection type: | Male connector, M8, 4-pin |
![]() |
![]() |
Supply voltage Vs: | DC 12 V (-5 %) ... DC 24 V (+10 %) |
![]() |
![]() |
Power consumption 1): | ≤ 1.92 W |
![]() |
![]() |
Warm-up time: | ≥ 5 min |
![]() |
![]() |
Indication: | 4-digit 7-segment display (plus 4 LEDs for status display) |
![]() |
![]() |
Operating elements: | 4 buttons |
![]() |
![]() |
Weight: | 70 g |
![]() |
![]() |
Dimensions: | 44.4 mm x 31 mm x 17 mm |
![]() |
![]() |
Housing material: | Stainless steel housing with PPSU lens |
![]() |
![]() |
1) Without load, with current output |
![]() |
Ambient data |
|||
![]() |
Enclosure rating: | IP 67 |
![]() |
![]() |
Protection class: | III |
![]() |
![]() |
Ambient temperature: | Operation: -10 ... +40 °C, Storage: -20 ... +60 °C |
![]() |
![]() |
Min. rel. humidity (not condensing): | 35 % |
![]() |
![]() |
Max. rel. humidity (not condensing): | 95 % |
![]() |
![]() |
Temperature drift: | ± 0.08 % FS/K (FS = Full Scale = Measuring range of sensor) |
![]() |
![]() |
Vibration resistance: | 10 Hz ... 55 Hz (amplitude 1.5 mm, x-, y-, z-axis 2 hours each) |
![]() |
![]() |
Shock resistance: | 50 G (x-, y-, z-axis 3 times each) |
![]() |
![]() |
Typ. Ambient light immunity: | Artificial light: ≤ 3,000 lx, Sunlight: ≤ 10,000 lx |
![]() |
![]() |
![]() |
General notes |
|||
![]() |
Note: | Not free of paint wetting impairment substances. |